A bottle or jar that looks right on screen can still leak in transit, react with your formula or refuse to hold a label. Samples let you find those problems before you've bought a case. Here's how our sample program works, what to test, and a simple checklist for testing packaging samples before you place a bulk order.
- 10 itemsUp to 10 different products per sample request
- 1 eachOne unit of each item
- $10Flat shipping for the sample order
How free samples work
You can request one each of up to 10 different items, and pay $10 for shipping. To add an item, use the Get Free Sample button on the product page. Samples are available for items that are in stock.
Ten items goes further if you plan the request. Instead of ten bottles, think in complete packages: a bottle, the cap or pump that fits it, and a second closure option to compare. For example:
- One PET jar, one PP jar, a smooth cap and a dome cap to compare looks.
- One bottle with a lotion pump, a disc-top cap and a snap-top cap to compare dispensing.
- One jar with a cap that has a heat seal liner and one with a pressure-sensitive liner to compare seals.
If you'd rather test with more units, there's no minimum order. Single units can be purchased, so you can buy a few of the same item for side-by-side tests before ordering in bulk.
What to test
Fit and neck finish
Confirm the cap, pump or sprayer threads on smoothly, sits level and tightens fully. The neck finish (such as 24-410 or 70-400) must match on both parts. For pumps and sprayers, check the dip tube length reaches the bottom of the bottle.
Leaks
Fill with your actual product, tighten the cap the way you will in production, then lay it on its side and turn it upside down overnight. Squeeze it gently. Any seepage at the rim means you need a different liner, cap or torque.
Compatibility over time
Some reactions take weeks to appear: paneling (sides caving in), swelling, cracking, discoloration, odor changes or the product separating. Leave filled samples for several weeks, including in heat and cold if your product will see them in shipping or storage.
Liner adhesion and seals
For pressure-sensitive and heat seal (induction) liners, check that the liner bonds fully around the rim and peels off cleanly. Induction seals depend on your sealing equipment and settings, so test with the equipment you'll actually use. See the Liner Guide.
Dispensing output
For pumps, sprayers and dispensing caps, check how much product comes out per use, the spray pattern, and whether thick products flow at all. A pump that works with lotion may struggle with a heavy cream.
Labeling and appearance
Apply your real label. Check that it fits the flat panel, conforms to curves and stays put when the container is squeezed, chilled or handled with oily hands. Look at the color and clarity with your product inside.
Why suppliers differ, even at the same finish
Neck finishes follow an industry standard, but the standard allows small tolerances. Two caps labeled 28-410 from different manufacturers can differ slightly in thread depth, liner thickness or how far they travel before they seal. Those small differences can change whether a combination seals perfectly or seeps.
Resin grade, wall thickness and colorants also vary from one manufacturer to the next. If you're switching suppliers, even for a bottle that looks identical, test samples of the new component with your product rather than assuming it will behave the same.
Test the exact combinationTest the bottle, closure and liner together, from the same source you'll order from, with your final formula. Changing any one of them is a reason to test again.
Step-by-step sample testing checklist
- Plan the request. List the complete packages you want to compare, and confirm each container and closure share the same neck finish.
- Order samples. Use the Get Free Sample button on each product page, up to 10 items. Buy extra single units if you need duplicates.
- Inspect on arrival. Check dimensions, color, clarity and thread fit before filling.
- Fill with your real product. Use the final formula at the fill level and temperature you'll use in production.
- Close as you will in production. Apply the same torque, and run the induction sealer if you're using heat seal liners.
- Leak test. Store some samples on their side and upside down, and squeeze gently.
- Age test. Keep filled samples at room temperature, in a warm spot and in the cold, if your product will see those conditions. Check them weekly for several weeks.
- Test dispensing. Run pumps, sprayers and dispensing caps through repeated uses and note the output.
- Apply labels. Check fit, adhesion and appearance after handling and temperature changes.
- Write it down. Record the exact product names and neck finishes that passed so your bulk order matches what you tested.
Who is responsible for compatibility
Compatibility testing is the customer's responsibility. Every formula is different, and storage conditions, fill temperatures and closing methods all affect how packaging performs. We'll share what we know about materials and components to help you choose what to test, but we can't guarantee that a specific container or closure will be compatible with your product. Testing samples is the way to confirm it.
Common questions
How many samples can I request?
One each of up to 10 different items, with $10 shipping.
How do I request a sample?
Click the Get Free Sample button on the product page. Samples are available for in-stock items.
What if I need more than one of an item?
There's no minimum order, so you can buy single units of any item to test alongside your free samples.
How long should I test before ordering in bulk?
Leak and fit problems usually show up within a day or two. Compatibility problems such as paneling, swelling or discoloration can take several weeks, so allow time for an age test, especially for oils, solvents and products with essential oils.
Can you tell me if my product is compatible?
We can help you choose materials and components that are commonly used for products like yours, but we can't guarantee compatibility. Testing your formula in samples is the only way to be sure.
Need help choosing what to sample?
Tell us about your product and we'll suggest containers and closures to test. Call (208) 550-3393 or send us a message.